Discreet heating installed in a reception tent

Power & heating

Event generator hire & event heating

A venue without enough power, a tent at 12 °C: two ways to spoil an evening. Generators from 3 to 100 kVA with their backup, distribution by use, and the heating that keeps guests in until dessert.

Power sized to volume and season
Installed and commissioned by our teams
Power distribution properly sized
Backup generator included from 20 kVA

Our solutions

Power everything, heat the space.

Heating is calculated in kilowatts per tent volume and season; power, by adding caterer, lighting, sound and heating. We do both calculations, and both installations.

Generator & power distribution

Generator & power distribution

Indirect gas heater

Indirect gas heater

Discreet ducted heating

Discreet ducted heating

Electric heaters & gas patio heaters

Electric heaters & gas patio heaters

Generator

Which generator for how many guests?

Our starting points. The final size depends on the loads to supply: electric heating or hot cooking on site can push it up a notch.

GeneratorFor which eventSame-power backup
3 kVATop-up or light backup (small sound system, lighting)No
20 kVAReception up to ~150 guestsIncluded
40 kVAWedding or reception of ~150 to 200 guestsIncluded
60 kVAWedding or reception of ~200 to 250 guestsIncluded
100 kVAFestival, large event, heavy installationIncluded

Weekend package: generator, changeover panel, 32 or 63 A distribution board and about 50 m of cable.

All in the same quote

The calculation nobody else wants to do for you.

Caterer (ovens, fridges), sound, lighting, heating: every lot draws on the same supply, and it always trips at dessert. Because we operate all the lots, we add up the real loads, size the source (venue supply or generator) and wire one distribution line per use.

  • Power estimated from all your loads
  • Generator if the venue lacks supply
  • Dedicated lines for caterer / sound / light / heating
  • Same-power backup generator included from 20 kVA

Guide prices

Ranges exclude transport, which is pooled with your structure in the overall quote.

Indirect gas heater (per day)
€180 – 350
Premium ducted heating (per day)
€300 – 700
Gas patio heater (per day)
€80 – 140
Full heating solution, 200 m² marquee (weekend, fuel incl.)
€1,500 – 4,000
Generator 20 to 100 kVA, backup included (weekend package)
€1,100 – 2,600
Power distribution (boards, dedicated lines)
per power audit

Guide ranges depending on power, duration and season, with fuel and consumables itemised in the quote. Book early for September to December, when heating demand triples.

Frequently asked questions about heating and power

Allow around 35 to 45 W per m³ in mid-season and up to 60 W per m³ in deep winter. For a 200 m² marquee (about 600 m³), that means 25 to 30 kW in mid-season and 35 to 45 kW in winter to reach 18-20 °C. Closed walls, lining and a floor can halve the requirement: we do the exact calculation for your structure, season and use.

The indirect heater sits outside with ducted distribution: the noise stays out. For weddings, premium ducted heating is nearly inaudible inside the tent.

That is the case for most estates and gardens: a generator takes over. We size it (3 to 100 kVA) by adding up the loads to supply (caterer, sound, lighting, heating) with a safety margin, and from 20 kVA a backup generator of the same power is included as standard.

It is itemised separately, never discovered on the day. For the generator, a weekend fuel package (about 150 L, roughly twelve hours of running) is offered in the quote; beyond that, actual consumption is charged. Heating gas is priced according to duration and season.